Installation of the Vector Tool Platform on a Computer

Vector Platform Manager » Procedures » Installation of the Vector Tool Platform on a Computer

General

CANoe /CANalyzer offers the possibility to execute real-time relevant simulation parts on any computer (RT server), independent of the graphical CANoe/CANalyzer user interface on the actual user computer (distributed mode).

This page explains how to run any computer on which the Vector Tool Platform (VTP) has not yet been preinstalled as an RT server.

Installation of Vector Tool Platform

In order to be able to operate any computer as an RT server, it is necessary to install the Vector Tool Platform on this computer. The following prerequisites are mandatory and restrictions apply.

Prerequisites

The following technical requirements are necessary to install VTP on a (standard) computer:

Installation

The following steps are necessary to install on a (standard) computer:

Procedure

Step by Step Procedure

  1. On the computer to be operated as RT server, execute the installation file Vector VTP Control Server.msi. (It is located in the installation directory of the Vector Platform Manager in the subdirectory Installer Additional Components. Examplt: C:\Program Files (x86)\Vector Platform Manager\Installer Additional Components\Vector VTP Control Server.msi.

    Note

    Note

    The following files and directories are created:

    • C:\VtpControlServer\ (corresponds to the subdirectory ..\VtpDrivers\x32\VectorToolPlatform\VtpControlServer\ of the Vector Platform Manager installation)
    • C:\rth\versions.json (File from ..\VtpDrivers\x32\VectorToolPlatform\common\rth\ of the Vector Platform Manager installation)
    • D:\VtpCs\Logging\LoggingConfig.json (newly created default logging configuration)
  2. On the (Standard) computer to be run as RT server start the following applications:
    • C:\VtpControlService\ControlServiceConsole.exe
    • C:\VtpControlService\ControlServer.exe
    • Note

      Note

      • ControlServer.exe requires administrator rights and should not be called with the parameters --firstrun , --install and --uninstall, as this might have influence on a possibly parallel CANoe/CANalyzer installation on the (standard) computer.
      • If an automatic start of VTP with the boot of the (standard) computer is desired, the applications can be manually included in the autostart process (under Windows 10 the Windows User Account Controls (UAC) must be deactivated and the Windows Registry Key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System\EnableLUA set to 0x0).
  3. On the user computer (distributed mode), start CANoe/CANalyzer and configure the distributed mode with the new RT server (confirm a possible request to install/update CANoe/CANalyzer to the RT server). After the update, the (standard) computer can be operated as RT server with the restrictions (see below) and can be reached via CANoe/CANalyzer or the Vector Tool Platform.

Restrictions

After installing VTP (see Installation above), the following limitations apply:

Deinstallation

The following steps are necessary to uninstall the installed VTP installation (see Installation above):

Procedure

Step by Step Procedure

  1. Close the following applications on the (standard) computer or the RT server:
  • C:\VtpControlService\ControlServiceConsole.exe
  • C:\VtpControlService\ControlServer.exe
  • Note

    Note

    The ControlServerConsole can be terminated by right-clicking on the upper right corner of the window while holding down the <Ctrl> key.

  1. Uninstall the Vector VTP Control Server application from the Control Panel.
  2. Note

    Note

    The following directories and subdirectories are deleted:

    • C:\VtpControlServer\
    • C:\rth\
    • C:\CANrtk\
    • C:\ProgramData\Vector\VectorToolPlatform\
    • D:\RTApplications\
    • D:\RTApplications_temp\
    • D:\VtpCs\
  3. Remove a possibly created automatic start of
  • C:\VtpControlService\ControlServiceConsole.exe
  • C:\VtpControlService\ControlServer.exe