Testmodule Gateway Tester Version
General Test Information
System Under Test
ECU name: Gateway
ECU version: 1.0
Test Engineer
Name: Büttner
Test Setup
Version of test configuration: 1.0
Test configuration created by: Alexander
Test Overview
Test Structure
1. Stimulate environment variables
1.1 Start Logging
1.2 Stimulate Car-Locking-System
1.3 Stimulate Ignition-Key
1.4 Stimulate Passanger-Setting
1.5 Wait for 10 more seconds after the stimulation and purely observe
1.6 Stop Logging
Test Case Details
Conditions
Distances:
Min Max Reference message type Reference message id Reference message bus Observed message type Observed message id Observed message bus Executed in variants
CAN msg Ignition CAN All
Requestresponse check:
Settings:
Min time: 50
Timeout: 1000ms
Request:
Type Name Bus
CAN msg Ignition CAN
Response:
Type Name Bus This object Reference object
Requestresponse check:
Settings:
Min time: 50
Timeout: 1000ms
Request:
Type Name Bus
CAN msg Driver_ID CAN
Response:
Type Name Bus This object Reference object
Requestresponse check:
Settings:
Timeout: 1000ms
Request:
Type Name Bus
CAN msg Driver_ID CAN
Response:
Type Name Bus This object Reference object

1 Test Group: Stimulate environment variables

1.1 Test Case : Start Logging

Sequence:

Initialize Pattern Start Logging

Wait:
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvLoggingControl - - - 1 All

1.2 Test Case : Stimulate Car-Locking-System

Sequence:

Initialize Pattern Select EnvOpenCar

Wait: 10
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvOpenCar - - - 1 All

Initialize Pattern EnvOpenCar

Wait: 2000
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvOpenCar - - - 0 All

1.3 Test Case : Stimulate Ignition-Key

Sequence:

Initialize Pattern Select EnvIgnitionSwitch

Wait: 5000
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvIgnitionSwitch - - - 1 All

Initialize Pattern Select EnvIgnitionSwitch

Wait: 2000
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvIgnitionSwitch - - - 0 All

1.4 Test Case : Stimulate Passanger-Setting

Sequence:

Initialize Pattern Select EnvDriver

Wait: 3000
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvDriver - - - 1 All

Initialize Pattern Select EnvDriver

Wait: 3000
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvDriver - - - 0 All

1.5 Test Case : Wait for 10 more seconds after the stimulation and purely observe

Sequence:

Until End Pattern

Time: 10s

1.6 Test Case : Stop Logging

Sequence:

Initialize Pattern Stop Logging

Wait:
Settings:
Type Name Message Node Bus Value Used in variants
Environment Variable EnvLoggingControl - - - 0 All

End of Testmodule