Version history CANoe Option ISO11783 Professional - ISO11783 database ================================================================================== 0. Table of Contents ---------------------------- 1. Copyright 2. Version history 1. Copyright -------------- (c) 2001-2018 Vector Informatik GmbH 2. Version History -------------------- +++ Version 11.0 SP2 - Value Tables with TIM Authentication Error Codes adjusted +++ Version 10.0 SP2+++ - Messages AUTH12, AUTH21, TIM12, TIM21 +++ Version 10.0 +++ - Add new signals with DDI = 353 to 521 - Create Value Table for DDI with 523 values - for all existing DDIs - create Value Table für ManufacturerCode und use it in ACL, CA, PD, VT12, VT21, WSMEM - Signal LanguageCodeCmd: ByteOrder modified from "Motorola" to "Intel" +++ Version 9.0 SP4 +++ - Add signal OriginCommand for Process Data Acknowledge (PDACK) message - Message AISO: rename signal StopAllImplementOperations to StopAllImplOpSwitchState +++ Version 9.0 SP3 +++ - Add signal for the reserved bit in an address claimed message +++ Version 9.0 SP2 +++ - Add message "GNSSPosDeltaHiPrecRapidUpdate" - Swap signals "DeviceClassInstance" and "IndustryGroup" in message VT12 +++ Version 9.0 +++ - Adjust Layout of 'VT Change String Value response' - Add new signal 'Status_3' to 'Auxiliary Input Type 2 Maintenance message' (VT21) +++ Version 8.5 SP3 +++ - Message Network renamed to Nxx (conform to J1939 Digital Annex), content (multiplexor and signals) adjusted - SigType for signals of PII message set to StringDelimiter +++ Version 8.5 +++ - Corrected: Data type of signal SF_Offset (message FSClient) ist signed +++ Version 8.2 SP3 +++ - Add new Signals for the messages ICC, TFR, RTF, FHS, RHS, FPTO, RPTO, AVooEF, AV15EF, AISO, DSS - Add new message HB ("Heartbeat") - Add new signals for DDIs 326-352 - Add new abort reasons for TPCM::ConnectionAbortReason and ETP_CM::ConnectionAbortReason +++ Version 8.2 SP2 +++ - Add new signals for Execute Extended Macro response - Add new signal for additional error code of VT Change Soft Key Mask message - Remove signals for Execute Op Code command and VT OpCode Notification message +++ Version 8.1 SP2 +++ - In the Value Table of signal ControllByte additional values inserted (64-67 and 128-133) - New signal BIECUPort aund NumberOfSaOrNamePairs created - Value tables for signals FromPort, ToPort, BIECUPort and NumberOfSaOrNamePairs created, SPNs defined. +++ Version 8.1 +++ - Messages DP, ICC: add new signals or remove uncommitet signals - Add new messages DSS, DSC with signals - Add new signals w/o messages - VT21/VT21: new commands "Auxiliary Capabilities Request/Response", "Extended Delete Version", "Extended Load Version", "Extended Store Version", "Execute OpCode", "Execute Extended Macro" and "VT OpCode Notification" - Update of manufacturer codes and global functions - Add new DDIs (263-321 and 57342) +++ Version 8.0 SP3 +++ - PD: In peer control assignment responses the signals for the NAME (of the CF) are not available +++ Version 8.0 +++ - Add new node attributes for the ISO11783 Interaction Layer - Add new signals with 153 < DDI < 263 to the message PD - Add new Version Message signals - Add Activate/Deactivate Object Pool command - Change PDNACK to PDACK and add new error codes - Change some signal names to avoid CANdb++ consistency check warnings - PD: Add Peer Control Assignment command - Rename LIC to LCMD according to J1939 - Update manufacturer codes and functions +++ Version 7.6 SP3 +++ - new paramter group NM (0x9300) +++ Version 7.6 +++ - VT21: new sub command values of Graphics Context command +++ Version 7.5 SP2 +++ - new paramter groups SCCCM and SCMCC (defined in ISO11783-14) - small corrections +++ Version 7.5 +++ - remove ISO11783_IL3.dbc and replace ISO11783_IL4.dbc by ISO11783.dbc - VT21: new commands "Get Supported Objects" and "Get Window Mask Data" - add messages IOS and AIOS - add File Server command 'Volume Status Response/Request' - add new SPNs- update manufacturer codes - use multiple multiplexor for WSMaintenanceInitiating to distinguish between IL3 and IL4 - update error codes of File Server messages - switch some signals from Signed to Unsigned - VT12: add boot time signal of command "Get Hardware response" - add message COGSOGRapidUpdate +++ Version 7.2 SP3 +++ Modifications for ISO11783_IL3 and ISO11783_IL4 - add signal 'connectionAbortReason' - change signal names of TPCM and ETP_CM Modifications for ISO11783_IL4 - rename VT12/VT21 command 'DisplayActivation' to 'VTOnUserLayoutHideShow' and modify used signals - change name of VT12/VT21 command 'InputStringValue' to 'VTChangeStringValue' - add VT12/VT21 command 'IdentifyVT' - add signals for method PDNACK of parameter group PD - increase length of signal 'MemoryRequired' from 3 to 4 - rework message 'PD' and its signals +++ Version 7.2 +++ - fixed invalid multiplexing information for messages CA, PD, TPCM and ETP_CM - use extended multiplexors for Process Data message - set signal type of signal LanguageCmdCode to ASCII - use new VT function codes for auxiliary assignment type 2 (32->36) and auxiliary input status type 2 (33->38) for IL4 - shift some signals to the correct postion within the message - update message ACKM +++ Version 5.1 +++ - added signal ECUManufacturerName in message ECUID - added singal VTBusyCode7 in message VT12 - update signal WSMaintenanceVersion (previous WSMaintenanceBitmask) - correct signals LocalMinuteOffset LocallHourOffset of message TD - added new SPNs - added following messages (ISO11783-12): MSS GPV4 DM3 - correct signal sequence in message ICC and other messages +++ Version 4.1 SP2 +++ - fixed some wrong SigType attribute values +++ Version 4.1 SP1 +++ - added value table for VT sub command Graphic Context - fixed multiplexor signal of PD message - fixed signal offset in ACL message - set attribute SigType of messages PD, FSClient, FSServer, VT12 and VT21 to default value +++ Version 4.1 +++ - databases are renamed to ISO11783_IL4.dbc and ISO11783_IL3.dbc to support implementation level 3 and 4 - modified address claiming message (EE00). Signals have now value tables for manufacturers - added signal to valve messages, front/rear PTO and hitch messages (AVxMF, AVxEF, FPTO,FHS,RPTO,RHS) - added following messages (ISO11783-12): SOFT ECUID DM1 DM2 - fixed value table issue of ETP_CM:ControlByte - ISO11783_IL4: Add value table for Busy Code 5 of VT Status Message (VT12) - ISO11783_IL4: Correct signals and value tables of 'Get hardware response' (VT12) - ISO11783_IL4: Add value table for signal TouchState of the Pointing Event command (VT12/VT21) - ISO11783_IL4: Add signal VTSelectInputObjectIsEdited to VT12 - ISO11783_IL4: Add Get Supported WideChars command/response - ISO11783_IL4: Add proportional font type (Get Text Font Data Response) +++ Version 4.0 +++ - renamed parameter groups to acronyms of ISO11783-1 - new database ISO11783_IL4Draft.dbc added. This DBC contains changes of ISO11783-6 Draft from 2006-12-12. The ISO11783.dbc contains messages for implementation level 3. - VT12 New command 'LockUnlockMaskResponse' New command 'ExecuteMacroResponse' New command 'SetObjectLabelResponse' New command 'ChangePolygonPointResponse' New command 'ChangePolygonScaleResponse' New command 'GraphicsContextCmdResponse' New command 'GetAttributeValueResponse' New command 'SelectColourMapResponse' Modified command 'AuxiliaryInputStatus' Modified command 'AuxiliaryAssignment' New command 'AuxiliaryPreferredAssignmentResponse' New command 'AuxiliaryInputEnable' - VT21: Update some commands according to 11783_06_N369_2006-10-18.doc New command 'LockUnlockMask' New command 'ExecuteMacro' New command 'SetObjectLabel' New command 'ChangePolygonPoint' New command 'ChangePolygonScale' New command 'GraphicsContextCmd' New command 'GetAttributeValue' New command 'SelectColourMap' Modified command 'AuxiliaryAssignmentResponse' New command 'AuxiliaryPreferredAssignment' New command 'AuxiliaryMaintenance' New command 'AuxiliaryInputEnableResponse' +++ Version 3.2 SP +++ - fixed: Wrong signal value tables for TractorFacilitesResponseMessage and RequiredTractorFacilitesMessage +++ Version 3.2 +++ - converted database to CANoe 5.2 format - add process data from ISO11783-11 2005-08-25 - updated file server messages to ISO11783-13 2005-07-14 - fixed: signal EngineSpeed of EEC1 uses Motorola instead of Intel format