<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<IP DBVersion="V4.0" IPType="peripheral" Name="PWR" Version="STM32L55_pwr_v1_0"
	xmlns:ns0="http://www.w3.org/2001/XMLSchema-instance"
	ns0:schemaLocation="http://mcd.rou.st.com/modules.php?name=mcu ../../../../../../../doc/V4/Development/Specifications/db/IP_Modes.xsd"
	xmlns="http://mcd.rou.st.com/modules.php?name=mcu">
	<About>PWR: Power</About>
	
	<RefParameter Comment="Instance" DefaultValue="PWR" Name="Instance" Type="" Visible="false"/>
	<RefParameter Comment="PVD detection Level" DefaultValue="PWR_PVDLEVEL_7" Name="PVDLevel" Type="list" Visible="false">
		<Condition Expression="Sem_ExternalAnalogVoltage" Diagnostic="" />
		<PossibleValue Comment="PWR PVD LEVEL 7" Value="PWR_PVDLEVEL_7" />
	</RefParameter>
	<RefParameter Comment="PVD detection Level" DefaultValue="PWR_PVDLEVEL_0" Name="PVDLevel" Type="list">
		<Condition Expression="!Sem_ExternalAnalogVoltage" Diagnostic="" />
		<PossibleValue Comment="PWR PVD LEVEL 0 (2.0 V)" Value="PWR_PVDLEVEL_0" />
		<PossibleValue Comment="PWR PVD LEVEL 1 (2.2 V)" Value="PWR_PVDLEVEL_1" />
		<PossibleValue Comment="PWR PVD LEVEL 2 (2.4 V)" Value="PWR_PVDLEVEL_2" />
		<PossibleValue Comment="PWR PVD LEVEL 3 (2.5 V)" Value="PWR_PVDLEVEL_3" />
		<PossibleValue Comment="PWR PVD LEVEL 4 (2.6 V)" Value="PWR_PVDLEVEL_4" />
		<PossibleValue Comment="PWR PVD LEVEL 5 (2.8 V)" Value="PWR_PVDLEVEL_5" />
		<PossibleValue Comment="PWR PVD LEVEL 6 (2.9 V)" Value="PWR_PVDLEVEL_6" />
	</RefParameter>

	<RefParameter Comment="PWR PVD Mode" DefaultValue="PWR_PVM_MODE_NORMAL" Name="Mode" Type="list">
		<Description>Mode: Specifies the PVD trigger mode.</Description>
		<PossibleValue Comment="basic mode is used" Value="PWR_PVD_MODE_NORMAL" />
		<PossibleValue Comment="External Interrupt Mode with Rising edge trigger detection" Value="PWR_PVD_MODE_IT_RISING" />
		<PossibleValue Comment="External Interrupt Mode with Falling edge trigger detection" Value="PWR_PVD_MODE_IT_FALLING" />
		<PossibleValue Comment="External Interrupt Mode with Rising/Falling edge trigger detection" Value="PWR_PVD_MODE_IT_RISING_FALLING" />
		<PossibleValue Comment="Event Mode with Rising edge trigger detection" Value="PWR_PVD_MODE_EVENT_RISING" />
		<PossibleValue Comment="Event Mode with Falling edge trigger detection" Value="PWR_PVD_MODE_EVENT_FALLING" />
		<PossibleValue Comment="Event Mode with Rising/Falling edge trigger detection" Value="PWR_PVD_MODE_EVENT_RISING_FALLING" />
	</RefParameter>
	
	<RefParameter Comment="PWR Full Privilege" DefaultValue="PWR_PRIVILEGE_FULL_NO" Group="Privilege PWR" TabName="TZSC Privilegeable PWR"  Name="pwrPrivilegeFull" Type="list">
        <PossibleValue Comment="Enable" Value="PWR_PRIVILEGE_FULL_YES"  />
        <PossibleValue Comment="Disable" Value="PWR_PRIVILEGE_FULL_NO"  />
        
    </RefParameter>
    <RefParameter Comment=" PWR full secure" DefaultValue="PWR_SECURE_FULL_YES" Group="Secure PWR" TabName="TZSC Securable PWR"  Name="pwrSecureFull" Type="list">
        <Condition Diagnostic="" Expression="S_SECURE"/>

        <PossibleValue Comment="Enable" Value="PWR_SECURE_FULL_YES"  />
        <PossibleValue Comment="Disable" Value="PWR_SECURE_FULL_NO"  />
            

     
    </RefParameter>
    <RefParameter Visible="false" Name="ItemSECPRIV" Comment="" Type="list" DefaultValue="PWR_ALL"/>
    
     <RefParameter Visible="false" Name="AttributesSECPRIV" Comment="" Type="list" DefaultValue="PWR_SEC | PWR_PRIV">
        <Condition Diagnostic="items SEC &amp; PRIV" Expression="(pwrSecureFull=PWR_SECURE_FULL_YES) &amp; (pwrPrivilegeFull=PWR_PRIVILEGE_FULL_YES)"/>
    </RefParameter>
    <RefParameter Visible="false" Name="AttributesSECPRIV" Comment="" Type="list" DefaultValue=""/>
    
    <RefParameter Visible="false" Name="AttributesPRIV" Comment="" Type="list" DefaultValue="PWR_PRIV">
        <Condition Diagnostic="items PRIV" Expression="pwrPrivilegeFull=PWR_PRIVILEGE_FULL_YES"/>
    </RefParameter>
    <RefParameter Visible="false" Name="AttributesPRIV" Comment="" Type="list" DefaultValue=""/>
    
    <RefParameter Visible="false" Name="AttributesSEC" Comment="" Type="list" DefaultValue="PWR_SEC">
        <Condition Diagnostic="items SEC" Expression="pwrSecureFull=PWR_SECURE_FULL_YES"/>
    </RefParameter>
    <RefParameter Visible="false" Name="AttributesSEC" Comment="" Type="list" DefaultValue=""/>
    
    
   <RefParameter Comment="High impedance mode" DefaultValue="null" Name="HighImpedanceMode" Type="list" Visible="false"/>

	
	
	<RefParameter Comment="Internal Voltage reference scale" DefaultValue="null" Name="VoltageScaling" Type="list" Visible="false" />
	
	<RefParameter Comment="Trimming Mode" DefaultValue="__NULL" Name="TrimmingMode" Type="list">
	    <Condition Expression="Sem_InternalMode" Diagnostic=""/>
		<PossibleValue Comment="Factory Trimming" Value="__NULL" />
		<PossibleValue Comment="User Trimming" Value="USER_TRIMMING" />
	</RefParameter>
	
	<RefParameter Comment="Trimming Mode" DefaultValue="null" Name="TrimmingMode" Type="list" Visible="false" />
	
	<RefParameter Comment="Trimming Value" DefaultValue="0" Max="63" Min="0" Name="TrimmingValue" Type="integer">
    	<Condition Expression="TrimmingMode = USER_TRIMMING &amp; Sem_InternalMode" Diagnostic=""/>
    </RefParameter>
    
    <RefParameter Comment="Trimming Value" DefaultValue="null" Max="63" Min="0" Name="TrimmingValue" Type="integer" Visible="false"/>

	<RefParameter Comment="UCPD Disable Dead Battery Signals" DefaultValue="null" Name="DisableDeadBatterySignalsConfig" Type="list" Visible="false">
		<Condition Expression="SEM_M33NS" Diagnostic=""/>
	</RefParameter>
	<RefParameter Comment="UCPD Disable Dead Battery Signals" DefaultValue="Disable" Name="DisableDeadBatterySignalsConfig" Type="list" Visible="false">
		<Condition Expression="UCPD1_Exist &amp; !S_UCPD_ModeUCPD1" Diagnostic=""/>
		<PossibleValue Comment="S_UCPD_ModeUCPD1" Value="Disable"/>
	</RefParameter>
    <RefParameter Comment="UCPD Disable Dead Battery Signals" DefaultValue="Disable" Name="DisableDeadBatterySignalsConfig" Type="list" Visible="false">
        <Condition Expression="!UCPD1_Exist" Diagnostic=""/>
        <PossibleValue Comment="!UCPD1_Exist" Value="Disable"/>
    </RefParameter>
	<RefParameter Comment="UCPD Disable Dead Battery Signals" DefaultValue="null" Name="DisableDeadBatterySignalsConfig" Type="list" Visible="false"/>

	<RefMode Name="Mode_PVD_Ext" Group="Programmable_Voltage_Detector_Settings">
		<ConfigForMode>PVDConfig</ConfigForMode>
		<ConfigForMode>PVDEnable</ConfigForMode>
                <ConfigForMode>ConfigAttributesSECPRIV</ConfigForMode> 
                <ConfigForMode>ConfigAttributesSEC</ConfigForMode>
                <ConfigForMode>ConfigAttributesPRIV</ConfigForMode>
                
		<Parameter Name="PVDLevel" />
		<Parameter Name="Mode" />
                 <Parameter Name="pwrPrivilegeFull"/>
                 <Parameter Name="pwrSecureFull"/>
	</RefMode>
	<RefMode Name="Mode_PVD_Int"  Group="Programmable_Voltage_Detector_Settings">
		<ConfigForMode>PVDConfig</ConfigForMode>
		<ConfigForMode>PVDEnable</ConfigForMode>
                 <ConfigForMode>ConfigAttributesSECPRIV</ConfigForMode> 
                 <ConfigForMode>ConfigAttributesSEC</ConfigForMode>
                <ConfigForMode>ConfigAttributesPRIV</ConfigForMode>
		<Parameter Name="PVDLevel" />
		<Parameter Name="Mode" />
                <Parameter Name="pwrPrivilegeFull"/>
                <Parameter Name="pwrSecureFull"/>
	</RefMode>
	<RefMode Name="DisableDeadBatterySignals">
		<ConfigForMode>DisableDeadBatterySignals</ConfigForMode>
		<Parameter Name="DisableDeadBatterySignalsConfig"/>
	</RefMode>

        <ModeLogicOperator Name="OR">
              <Mode Name="WakeUp0" UserName="Wake-Up 0">
			<ModeLogicOperator Name="OR">
				<Mode Name="WakeUp0">
					<SignalLogicalOp Name="AND">
						<Signal Name="WKUP1" />
					</SignalLogicalOp>
				</Mode>
			</ModeLogicOperator>
		</Mode>
		<Mode Name="WakeUp1" UserName="Wake-Up 1">
			<ModeLogicOperator Name="OR">
				<Mode Name="WakeUp1">
					<SignalLogicalOp Name="AND">
						<Signal Name="WKUP2" />
					</SignalLogicalOp>
				</Mode>
			</ModeLogicOperator>
		</Mode>
		<Mode Name="WakeUp2" UserName="Wake-Up 2">
			<ModeLogicOperator Name="OR">
				<Mode Name="WakeUp2">
					<SignalLogicalOp Name="AND">
						<Signal Name="WKUP3" />
					</SignalLogicalOp>
				</Mode>
			</ModeLogicOperator>
		</Mode>
		<Mode Name="WakeUp3" UserName="Wake-Up 3">
			<ModeLogicOperator Name="OR">
				<Mode Name="WakeUp3">
					<SignalLogicalOp Name="AND">
						<Signal Name="WKUP4" />
					</SignalLogicalOp>
				</Mode>
			</ModeLogicOperator>
		</Mode>
		<Mode Name="WakeUp4" UserName="Wake-Up 4">
			<ModeLogicOperator Name="OR">
				<Mode Name="WakeUp4">
					<SignalLogicalOp Name="AND">
						<Signal Name="WKUP5" />
					</SignalLogicalOp>
				</Mode>
			</ModeLogicOperator>
		</Mode>
		
        <Mode Name="PowerVD" UserName="Power Voltage Detector In">
			<ModeLogicOperator Name="XOR">
				<Mode Name="Mode_PVD_Ext"
					UserName="Power Voltage Detector In (External input analog voltage)">
					<SignalLogicalOp Name="AND">
						<Signal Name="PVD_IN" />
					</SignalLogicalOp>
					<Semaphore>Sem_ExternalAnalogVoltage</Semaphore>
					<Semaphore>PVD_INTERRUPT</Semaphore>

				</Mode>
				<Mode Name="Mode_PVD_Int"
					UserName="Power Voltage Detector In (Internal analog voltage)">
					<SignalLogicalOp Name="AND">
						<Signal Name="V_PVD_IN" />
					</SignalLogicalOp>
					<Semaphore>PVD_INTERRUPT</Semaphore>
				</Mode>
                                </ModeLogicOperator>
		</Mode>
		<Mode Name="DisableDeadBatterySignals" UserName="save power of non-active UCPD - deactive Dead Battery pull-up" RemoveDisable="true">
			<ModeLogicOperator Name="NONE">
				<Mode Name="DisableDeadBatterySignals" UserName="Dead Battery Signals disabled">
					<SignalLogicalOp Name="AND">
						<Signal Name="VS_DBSignals"/>
					</SignalLogicalOp>
					<Semaphore>SYS_DisabledDeadBattery</Semaphore>
				</Mode>
			</ModeLogicOperator>
		</Mode>
    </ModeLogicOperator>
                
 <!-- RefSignal for System -->
	
	<RefSignal IOMode="System" Name="WKUP1" />
	<RefSignal IOMode="System" Name="WKUP2" />
	<RefSignal IOMode="System" Name="WKUP3" />
	<RefSignal IOMode="System" Name="WKUP4" />
	<RefSignal IOMode="System" Name="WKUP5" />
	<RefSignal IOMode="Analog" Name="PVD_IN" />
	<RefSignal IOMode="Analog" Name="V_PVD_IN" Virtual="true" />
	<RefSignal Name="VS_DBSignals" Virtual="true"/>

        
        
        